VOI Stainless Steel Pantarsal Arthrodesis Plate
ORI3XX
These pre-contoured stainless steel pan-tarsal arthrodesis plates are designed to create excellent stabilisation across the tarsus while fusion of the joint occurs. The medial placement results in an increased area moment of inertia of the implants, compared to a plate of similar size placed cranially, meaning implant failure by cyclical fatigue is less likely. It also gives the surgeon the option to place an additional calcaneo-tibial screw if desired for extra security.
2.0 PA L
2.0mm/2.7mm Feline 120 degrees 9-Hole Left
VOI Stainless Steel Pantarsal Arthrodesis Plate - 2.0mm/2.7mm Feline 120 degrees 9-Hole Left
These pre-contoured stainless steel pan-tarsal arthrodesis plates are designed to create excellent stabilisation across the tarsus while fusion of the joint occurs. The medial placement results in an increased area moment of inertia of the implants, compared to a plate of similar size placed cranially, meaning implant failure by cyclical fatigue is less likely. It also gives the surgeon the option to place an additional calcaneo-tibial screw if desired for extra security.
Product #:
2.0 PA L
2.0 PA R
2.0mm/2.7mm Feline 120 degrees 9-Hole Right
VOI Stainless Steel Pantarsal Arthrodesis Plate - 2.0mm/2.7mm Feline 120 degrees 9-Hole Right
These pre-contoured stainless steel pan-tarsal arthrodesis plates are designed to create excellent stabilisation across the tarsus while fusion of the joint occurs. The medial placement results in an increased area moment of inertia of the implants, compared to a plate of similar size placed cranially, meaning implant failure by cyclical fatigue is less likely. It also gives the surgeon the option to place an additional calcaneo-tibial screw if desired for extra security.
Product #:
2.0 PA R
2.7 PA L
2.0mm/2.7mm Canine 136 degrees 9-Hole Left
VOI Stainless Steel Pantarsal Arthrodesis Plate - 2.0mm/2.7mm Canine 136 degrees 9-Hole Left
These pre-contoured stainless steel pan-tarsal arthrodesis plates are designed to create excellent stabilisation across the tarsus while fusion of the joint occurs. The medial placement results in an increased area moment of inertia of the implants, compared to a plate of similar size placed cranially, meaning implant failure by cyclical fatigue is less likely. It also gives the surgeon the option to place an additional calcaneo-tibial screw if desired for extra security.
Product #:
2.7 PA L
3.5 PA L
2.7mm/3.5mm 136 degrees 9-Hole Left
VOI Stainless Steel Pantarsal Arthrodesis Plate - 2.7mm/3.5mm 136 degrees 9-Hole Left
These pre-contoured stainless steel pan-tarsal arthrodesis plates are designed to create excellent stabilisation across the tarsus while fusion of the joint occurs. The medial placement results in an increased area moment of inertia of the implants, compared to a plate of similar size placed cranially, meaning implant failure by cyclical fatigue is less likely. It also gives the surgeon the option to place an additional calcaneo-tibial screw if desired for extra security.
Product #:
3.5 PA L
2.7 PA R
2.0mm/2.7mm Canine 136 degrees 9-Hole Right
VOI Stainless Steel Pantarsal Arthrodesis Plate - 2.0mm/2.7mm Canine 136 degrees 9-Hole Right
These pre-contoured stainless steel pan-tarsal arthrodesis plates are designed to create excellent stabilisation across the tarsus while fusion of the joint occurs. The medial placement results in an increased area moment of inertia of the implants, compared to a plate of similar size placed cranially, meaning implant failure by cyclical fatigue is less likely. It also gives the surgeon the option to place an additional calcaneo-tibial screw if desired for extra security.
Product #:
2.7 PA R
3.5 PA R
2.7mm/3.5mm 136 degrees 9-Hole Right
VOI Stainless Steel Pantarsal Arthrodesis Plate - 2.7mm/3.5mm 136 degrees 9-Hole Right
These pre-contoured stainless steel pan-tarsal arthrodesis plates are designed to create excellent stabilisation across the tarsus while fusion of the joint occurs. The medial placement results in an increased area moment of inertia of the implants, compared to a plate of similar size placed cranially, meaning implant failure by cyclical fatigue is less likely. It also gives the surgeon the option to place an additional calcaneo-tibial screw if desired for extra security.
Product #:
3.5 PA R